HONESTY IS THE ROOT
Quality is always satisfactory
Hotline
400-606-8981
LOCATION:Home > News > Company News >
NEWS CATEGORY
HOT PRODUCT
MORE
  • Coarse grained soil direct shear tester Coarse grained soil direct shear tester

    The coarse-grained soil direct shear tester is mainly used for on-site testing and research of dam ma...

  • Coarse grained soil consolidation tester Coarse grained soil consolidation tester

    The coarse-grained soil consolidation tester is used to determine the relationship between deformatio...

  • Coarse grained soil triaxial compression tester Coarse grained soil triaxial compression tester

    This testing machine adopts our company's servo pump control,which has low noise and energy consumpti...

  • Cement constant stress pressure testing machine Cement constant stress pressure testing machine

    This cement constant stress pressure testing machine is mainly used for compressive testing of cement...

  • Digital universal material testing machine Digital universal material testing machine

    The digital universal material testing machine is suitable for tensile, compressive, bending, shear a...

Characteristics, usage problems analysis and usage methods of electronic moisture analyzer

Dec 25

2024

NEWS DETAIL

The characteristics and usage problems analysis of electronic moisture analyzer

Speed suitable moisture analyzer is a faster and more suitable testing instrument for determining the moisture content of substances designed to simulate the national standard oven method than the oven method. The heat source of the heating system currently includes halogen lamps, infrared lamps, resistance wires, microwaves, etc. The sensors of the weighing system include electromagnetic sensors, strain gauges, and mechanical weighing sensors.

; The weighing accuracy generally varies from 0.002g to 0.001gFeatures of electronic moisture analyzer:Humanized human-machine interface design, beautiful appearance, and excellent performanceMultiple working modes meet various needs. (including conventional, fixed temperature and timing, custom, and estimated *)

Stable performance: Strain gauges have excellent stability

Real time status displayReal time detection during the testing processFully automatic fault detection with Chinese promptsEquipped with RS232C and U interfaces, it can connect to mini printers and computersConfigure the upper computer software to remotely control and operate the balance, and analyze and store the sampled data

Suitable speed for moisture analyzer usage:

It can accurately and quickly measure the moisture content of grains and other non-metallic granular samples such as rice, wheat, corn, soybeans, rapeseed, etc

Suitable speed for moisture analyzer usage mode:

1、 Automatic stop mode: It will automatically stop when the set value of moisture change (floating amplitude%) within 30 seconds is below

2、 Time stop mode: stops at a pre-set time (t1)

3、 Suitable speed drying mode: In the early stage of drying, use high temperature to dry it, and if the water is fed, return to the set temperature to shorten the measurement time

4、 Slow drying mode: Slowly dry samples that may form a film on the surface or decompose easily at high temperatures

5、 Step by step drying mode: Change the drying conditions in stages to measure samples with attached water, crystal water, and other high moisture content on the surface

6、 Prediction (Comparison) Measurement Mode: Predict the changes that will occur during the drying process, obtain the measurement value (MP), and shorten the measurement time

Common problems with using a moisture analyzer

1. Fully enclosed system issue: The connection of the reagent liquid circuit must be tightened, from the reagent bottle to the metering pump and then to the reaction tank. Otherwise, reagent leakage will directly affect the test results.

. Another issue with its unclosed nature is that during testing, the Karl Fischer reagent absorbs moisture from the air, which can cause a delay in the titration endpoint. Common issues with using a moisture analyzer

2、 Accuracy issue of sampling: When calibrating the reagent, 10mg of water should be taken, and a 10ul sampler should be used as much as possible. This not only ensures accuracy and appropriate speed, but also prevents water droplets from adhering. Similarly, there are similar issues with the use of methanol reagents and ethyl esters, and care should be taken to shorten the opening time of the reaction tank as much as possible after removal

3、 Magnetic stirring speed adjustment: In the reaction tank, because the titration reagent is added locally and not at the same location as the electrode, the stirring speed should be fast enough not to form turbulence, so as to reach the endpoint quickly

4、 The titration speed should be set from fast to slow: during titration, the speed should be appropriate to shorten the test time as much as possible, and the strain should be slow when approaching the endpoint, which can improve the measurement accuracy

5、 After the experiment is completed on that day, it is necessary to empty the Karl Fischer reagent from the system and clean it with methanol. Do not clean the system with water, as it is not easy to evaporate and will cause inaccurate calibration of the Karl Fischer reagent in the next experiment

6、 The moisture analyzer should be kept away from strong magnetic fields to avoid electronic display jumping and abnormal phenomena during operation. The manual moisture analyzer uses a glass automatic burette to measure the free reagent and methanol solvent, and the glass burette itself needs to be connected to the outside due to the balance pressure